NX600
Keep vital circuits alive in a fire
NX600 maintains circuit integrity during a fire
Alsecure® NX600 is a low smoke, halogen free, fire resistant cable approved for applications with survival timesof 30, 60, and 120 minute as described in BS8519 and is designed for use with fire safety engineering systems in buildings such as:
- The supply and control of smoke and fire barriers
- Smoke control equipment e.g. dampers, curtains, and fans
- Fire-fighting and evacuation lifts
- Sprinkler systems
- Wet riser pumps
- Plus other systems which help to ensure the safest evacuation and assist in the firefighting stages of a fire
Alsecure® are armoured fire resistant cables for 600/1000V with low emission smoke and corrosive gases when exposed to fire to further reduce the risk to life. They are designed as per BS7846 standard and are approved for the F2 and F120 fire test as per BS8491 standard.
The cable is halogen free, mica and XLPE insulated, LSF bedded, steel wire armoured LSF sheathed cable with annealed copper conductors.
In addition, the Alsecure cables have no extra tapes to remove, are easy to strip and retain their memory making them easy to install.
Confidence from independent certification
Further testament to the quality are the independant approvals obtained by Alsecure® NX600. Users can thus be sure that the Alsecure® NX600 will maintain power to their critical fire safety systems as they meet the highest and most exacting performance standards.
- BASEC approved: the British Approvals Service for Cables (BASEC) certification confirms that the Nexans Alsecure® NX600 range of enhanced fire resistant power cables has passed the BS7846-F-120 program of fire testing.
- LPCB approved: The Loss Prevention Certification Board (LPCB) has been working with industry and government for more than 100 years to set the standards needed to ensure that fire and security products and services perform effectively.
- LUL- S1085: London Underground compliant S1085 - Fire Safety Performance Of Materials - Stations and Tunnel Infrastructure
Nexans ' cable Alsecure® NX600 can be found listed online in the BASEC registry as well as on Red Book Live, the LPCB list of Approved Fire & Security Prodcuts and Services.
As electric cables are the backbone of vital fire safety systems, using fire-resistant cables increases the chances of evacuation, potentially saving lives, homes and businesses.
Full fire test performance
- BS 7846 F2-F120
- BS 8519 cat1-2-3
- BS 8491 F120
- IEC 60332-3-24
- IEC 60267-2..1/2.2
- IEC 61034-2
“ Building fires are dangerous but builders can improve the chances of escape by carefully choosing the materials used in construction. Building materials like Alsecure NX600 cables are ideal for use in vital circuits because of the fire resistant, low smoke and halogen free qualities. ”
Our websites
Select your country to find our products and solutions
-
Africa
- Africa
- Ghana
- Ivory Coast
- Morocco
- North West Africa
- Americas
- Asia
- Europe
- Oceania